HOW MANY ONE-COMPONENT CANS DO I NEED?
|
| |
| Handi-Foam 12oz. (340g) |
|
LINEAR FOOTAGE
|
| |
500 |
1000 |
1500 |
2000 |
2500 |
3000 |
3500 |
4000 |
4500 |
5000 |
| 1/4" (6.3 mm) |
1 |
1 |
1 |
2 |
2 |
2 |
3 |
3 |
3 |
4 |
| 3/8" (9.5 mm) |
1 |
2 |
2 |
3 |
4 |
4 |
5 |
6 |
6 |
7 |
| 1/2" (12.7 mm) |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
10 |
11 |
12 |
| |
152 |
305 |
457 |
610 |
762 |
914 |
1067 |
1219 |
1372 |
1524 |
|
LINEAR METERS
|
| Handi-Foam 24 oz. (680g) |
|
LINEAR FOOTAGE
|
| |
4,000 |
5,000 |
6,000 |
7,000 |
8,000 |
9,000 |
10,000 |
11,000 |
12,000 |
13,000 |
| 1/4" (6.3 mm) |
2 |
2 |
2 |
2 |
3 |
3 |
3 |
4 |
4 |
4 |
| 3/8" (9.5 mm) |
3 |
4 |
4 |
5 |
6 |
6 |
7 |
8 |
8 |
9 |
| 1/2" (12.7 mm) |
5 |
6 |
7 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
| |
1219 |
1524 |
1829 |
2134 |
2438 |
2743 |
3048 |
3353 |
3638 |
3962 |
|
LINEAR METERS
|
| Handi-Foam 31 oz. (880g) |
|
LINEAR FOOTAGE
|
| |
4,000 |
5,000 |
6,000 |
7,000 |
8,000 |
9,000 |
10,000 |
11,000 |
12,000 |
13,000 |
| 1/4" (6.3 mm) |
1 |
2 |
2 |
2 |
2 |
2 |
3 |
3 |
3 |
3 |
| 3/8" (9.5 mm) |
2 |
3 |
3 |
4 |
4 |
5 |
5 |
6 |
6 |
6 |
| 1/2" (12.7 mm) |
4 |
5 |
5 |
6 |
7 |
8 |
9 |
10 |
10 |
11 |
| |
1219 |
1524 |
1829 |
2134 |
2438 |
2743 |
3048 |
3353 |
3638 |
3962 |
|
LINEAR METERS
|
| Handi-Foam 160 |
|
LINEAR FOOTAGE
|
| |
10,000 |
20,000 |
30,000 |
40,000 |
50,000 |
60,000 |
70,000 |
80,000 |
90,000 |
100,000 |
1/4"
(6.3 mm) |
1 |
1 |
2 |
2 |
3 |
3 |
4 |
4 |
5 |
5 |
3/8"
(9.5 mm) |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
1/2"
(12.7 mm) |
2 |
4 |
6 |
8 |
10 |
12 |
14 |
15 |
17 |
19 |
| |
3,048 |
6,096 |
9,144 |
12,192 |
15,240 |
18,288 |
21,336 |
24,384 |
27,432 |
30,480 |
|
LINEAR METERS
|
| Handi-Foam 260 |
|
LINEAR FOOTAGE
|
| |
10,000 |
20,000 |
30,000 |
40,000 |
50,000 |
60,000 |
70,000 |
80,000 |
90,000 |
100,000 |
1/4"
(6.3 mm) |
1 |
1 |
1 |
2 |
2 |
2 |
2 |
3 |
3 |
3 |
3/8"
(9.5 mm) |
1 |
2 |
2 |
3 |
4 |
4 |
5 |
6 |
6 |
7 |
1/2"
(12.7 mm) |
1 |
2 |
4 |
5 |
6 |
8 |
9 |
10 |
11 |
12 |
| |
3,048 |
6,096 |
9,144 |
12,192 |
15,240 |
18,288 |
21,336 |
24,384 |
27,432 |
30,480 |
|
LINEAR METERS
|
1) Choose either the chart for 12 oz., 24 oz., 31 oz., 160 or 260.
2) Measure the adverage width of your gap. This equals your required bead size (left column).
3) Estimate the total linear footage of your application. Find the first number in the top row that exceeds the Linear Footage (bottom row if using Linear Meters). |
| |
|
HOW MANY TWO-COMPONENT KITS DO I NEED?
|
| |
|
SURFACE AREA FT2 (SURFACE AREA M2)
|
|
|
100 (9)
|
200 (19)
|
300 (28)
|
400 (37)
|
500 (47)
|
600 (56)
|
700 (65)
|
|
1" (2.5 CM)
|
100 (9)
|
200 (19)
|
300 (28)
|
400 (37)
|
500 (47)
|
600 (56)
|
700 (65)
|
|
2" (5 CM)
|
200 (19)
|
400 (37)
|
600 (56)
|
800 (74)
|
1000 (92)
|
1200 (112)
|
1400 (130)
|
|
3" (7.5 CM)
|
300 (28)
|
600 (56)
|
900 (84)
|
1200 (112)
|
1500 (139)
|
1800 (56)
|
2100 (65)
|
|
4" (10 CM)
|
400 (37)
|
800 (74)
|
1200 (112)
|
1600 (149)
|
2000 (47)
|
2400 (223)
|
2800 (260)
|
|
5"
(12.5 CM)
|
500 (47)
|
1000 (92)
|
1500 (139)
|
2000 (186)
|
2500 (232)
|
3000 (279)
|
3500 (325)
|
1) Find the unit of measure desired in the chart above (ft.2 or m2).
2) Determine the required thickness from far left column of chart.
3) Determine the required surface area (length x width) from the top row of chart.
4) The intersection of the row and column is the required surface area.
5) Refer to the bottom chart for the unit of measure required. Choose the desired product and divide the theoretical yield per kit into the required surface area. This is approximately how many kits are needed. |
| |
|
VOLUME FT3 (VOLUMEM2)
|
| 1 FT2 (.03) |
70 (2.0) |
140 (4.0) |
210 (5.9) |
280 (7.9) |
350 (9.9) |
420 (11.9) |
490 (13.9) |
| 10 FT2 (.3) |
80 (2.3) |
150 (4.2) |
220 (6.2) |
290 (8.2) |
360 (9.2) |
430 (12.2) |
500 (14.2) |
| 20 FT2 (.6) |
90 (2.5) |
160 (4.5) |
230 (6.5) |
300 (8.5) |
370 (9.5) |
440 (12.5) |
510 (14.4) |
| 30 FT2 (.8) |
100 (2.8) |
170 (4.8) |
240 (6.8) |
310 (8.8) |
380 (9.8) |
450 (12.7) |
520 (14.7) |
| 40 FT2 (1.1) |
110 (3.1) |
180 (5.1) |
250 (7.1) |
320 (9.1) |
390 (10.1) |
460 (13.0) |
530 (15.0) |
| 50 FT2 1.4) |
120 (3.4) |
190 (5.4) |
260 (7.4) |
330 (9.4) |
400 (10.4) |
470 (13.3) |
540 (15.3) |
1) Find the desired volume.
2) Refer to the chart above for the unit of measure required. Choose the desired product and divide the theoretical yield per kit into the required volume. This is approximately how many kits are needed. |
| |
|
|
|
|
|
|
|
| Item No. |
Product |
Square Feet (1" thickness) |
Square Meter |
Cubic Feet |
Cubic Meter |
| P10600 |
II-12
|
12
|
1.1
|
1.00
|
.03
|
| P10620 |
2-15
|
15
|
1.4
|
1.25
|
.04
|
| P10650 |
II-22
|
22
|
2.0
|
1.80
|
.05
|
| P10700 |
II-105
|
105
|
9.8
|
8.75
|
.25
|
| P10720 |
II-205
|
205
|
19.0
|
17.00
|
.48
|
| P10749 |
II-605
|
605
|
56.2
|
50.00
|
1.40
|
| * Yields are based on theoretical calculations, for comparison purposes, and will vary depending on ambient conditions and particular application. Other two-component foam product yields are shown on the specific Technical Data Sheet. These examples are representative of other products of similar size. |
|